IMSM is Intel’s firmware RAID format (Rapid Storage Technology and Matrix Storage Manager), common on desktop and workstation motherboards. Linux handles it through MD, and arrays commonly use RAID 0, 1, 5 and 10.
Overview
IMSM metadata sits in the last sectors of each member and begins with the signature Intel Raid ISM Cfg Sig.. It describes disks and one or more volumes (maps) with RAID level, stripe size, number of members and migration state. Volumes are usually RAID0, RAID1, RAID5 or RAID10.
History
- Introduced as Intel Matrix Storage Manager in 2001, later renamed Intel Rapid Storage Technology.
Structures
Offsets are in bytes from the start of the structure named in each heading. Field names are descriptive and are not an official specification. Fixed-width integers are shown as u/i (unsigned/signed) followed by bit width and byte order.
Read Map
| Offset | Size | Type | Field | Notes |
|---|---|---|---|---|
| at | 4 | u32 LE | – | |
| at | 4 | u32 LE | Start | |
| at + 48 + 4 * i | 4 | u32 LE | I | |
| at + 4 | 4 | u32 LE | Per Member | |
| at + 12 | 2 | u16 LE | – | |
| at + 14 | 1 | u8 | – | |
| at + 15 | 1 | u8 | – | |
| at + 16 | 1 | u8 | Embers | |
| at + 20 | 4 | u32 LE | Start | |
| at + 24 | 4 | u32 LE | Per Member |
Constants
Imsm Module
| Name | Value | Type | Notes |
|---|---|---|---|
| SignatureText | “Intel Raid ISM Cfg Sig. “ | string | |
| DiskEntrySize | 48 | int | |
| DevFixedSize | 164 – 52 | int |