SM2258XT SK Hynix V4 – MPTool R1226A – FW R1226B0.7z
Type
Mass production tool package
Controller
SM2258XT
NAND target
SK Hynix V4
Contents
43 files, 3.6 MB unpacked
Component versions
Component
Version
Date (decoded)
MPTool
R1226A
2018-12-26
ISP
R1226B0
2018-12-26
RDT
R1221A0
2018-12-21
DLL
R1226A
2018-12-26
MPISP
R1221A
2018-12-21
BootISP
R1122A
2018-11-22
DB
R1225
2018-12-25
Package
S0103A
2019-01-03
MPTool file version
0, 0, 1, 2
Dates are decoded from SMI version codes: the letter is the year (J = 2010 … Y = 2025) and the four digits are month and day.
Controller
SM2258XT: SATA 6Gb/s SSD controller, 4 NAND channels, DRAM-less, LDPC ECC.
Function
Silicon Motion mass production tool package. It initializes the drive, loads the controller firmware, scans and records bad blocks, and writes the drive identity (model, serial number, capacity). Packages that include RDT firmware can run a burn-in test before the final firmware is loaded. Running the tool re-initializes the drive; existing user data is lost.
Configuration profiles (1)
Profile
Selected flash
Capacity setting
RDT
Default.ini
Hynix,1Tbit,H27Q2T8QEA9B(V4)(SM2258XT)
0
Package contents
Path
Description
Size
Config\
Production configuration profiles
1 file, 3.6 KB
Dll\
MPTool libraries
1 file, 487.0 KB
DriveSetting\
Drive setting tables
5 files, 298.6 KB
Firmware\
Firmware images
16 files, 727.2 KB
FlashDB\
NAND parameter database
1 file, 31.7 KB
Linux File\
Files for the Linux MP tool
11 files, 671.6 KB
Log file\
Log output folder
empty
RDT File\
RDT (burn-in) results
empty
Tables\
Seed, strong-page and I2C tables
2 files, 12.0 KB
UFD_MP\
MPTool UI settings and error-code tables
2 files, 1012 B
default.ini
MPTool default settings
4.2 KB
ErrorCode.txt
Error-code list
15.1 KB
name.txt
Package version list
146 B
SM2258XTMPToolR1226A.exe
Executable
1.4 MB
Flash database (103 entries)
The FW tag column comes from Firmware/2258/FWTag.SET and names the firmware build each part needs. Parts with another tag, or no tag, need a different firmware build.
Part numbers are copied as written in the database. Variant lists the bracketed qualifiers from the entry (voltage, die count, generation). Flash ID shows the first six ID bytes stored for the entry.